P-41.1, r. 5 - Guidelines respecting odours caused by manure from agricultural activities

Full text
5. SEPARATION DISTANCES FOR FARM MANURE STORAGE SITES SITUATED MORE THAN 150 METRES FROM LIVESTOCK FACILITIES
When farm manure is stored outside the livestock facility, separation distances must be respected. They are established on the consideration that one livestock unit (LU) requires a 20 m3 storage capacity. For example, the value of parameter A, in the case of a 1,000 m3 capacity tank, corresponds to 50 LU. Once that equivalence has been determined, it is possible to determine the corresponding base distance using Table B. The formula multiplying the set of parameters B, C, D, E, F and G may then be applied. The following table illustrates cases where C, D and E equal 1, with G varying according to the neighbouring unit considered.
Separation distances for liquid manure storage sites3 situated more than 150 m from a livestock facility

___________________________________________________

Storage4 Separation distances (m)
capacity ____________________________________

Dwelling Protected Urbanization
(m3) immovable perimeter
___________________________________________________
1,000 148 295 443
___________________________________________________
2,000 184 367 550
___________________________________________________
3,000 208 416 624
___________________________________________________
4,000 228 456 684
___________________________________________________
5,000 245 489 734
___________________________________________________
6,000 259 517 776
___________________________________________________
7,000 272 543 815
___________________________________________________
8,000 283 566 849
___________________________________________________
9,000 294 588 882
___________________________________________________
10,000 304 607 911
___________________________________________________
3 For manure, multiply the above distances by 0.8.
4 For other storage capacity, effect the necessary calculations using a rule of apportionment or the data for parameter A.